Laminar Airflow catalog

Category: Laminar flow hoods
  • Description
  • Reviews (0)
Description

The clean zone is a clean space where the air flow is blown from top to bottom and the suspended particles in the air due to weighing or sampling are directed and absorbed towards the filters. As a result, the user and the product are protected from contamination.

Specifications of Laminar Airflow (LAF)

The body and legs are made of 1.5 mm thick iron sheet with electrostatic powder paint/ The body and legs are made of acid-proof stainless steel sheet.

Covering more than 90% of the internal cabin roof by the main filter to increase efficiency

French HEPA filter according to EN1822 certified standard

Efficiency of 70% filtered air into the hood and 30% into the laboratory

Full-time, 20-minute UV control with a 20-second delay

It has a DPT sensor to display the lifetime of the filters

FATECH brand PLC electrical system

7 inch color touch control panel with easy and advanced use

  • Demonstration of UV lamp operation
  • Show the function of the filter
  • Display, time and date

UV lamp

Filters can be changed by the user

Special wheeled base with lock

Vertical ventilation system

Strong ceiling lighting

There are two sockets in the door

Laminar Airflow (LAF) Components

This hood includes the following components.

  • French HEPA filter according to EN1822 certified standard
  • Glass alarm to maintain standard air circulation
  • 7 inch color touch control panel with easy and advanced use
  • Special wheeled base with lock
  • There are two sockets in the door
  • Strong ceiling lighting
  • UV lamp

Laminar Airflow (LAF) standards and facilities

This hood has the following features and standards:

  1. Pressure difference sensor of two filter heads, flow, temperature and humidity
  2. Preventive maintenance instructions
  3. Manuals
  4. Construction plans
  5. Electric maps
  6. Body material certificate
  7. Factory Test (FAT)
  8. Testing at the buyer’s factory (SAT)
  9. All documents and documents DQ, IQ, OQ

Laminar Airflow screen (LAF)

This BSC control system works with a color touch screen and the screen shows the real parameters of the environment and monitors the emergency situations. The system includes remote access for customer service support. If needed, it is possible to connect to an additional device for storing and transferring production data.

Laminar flow hood display screen, class II, type B2

Laminar flow hood display screen, class II, type B2

Shape of maps:

Laminar Airflow schematic map

Laminar Airflow schematic map

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Laminar Airflow (LAF)” Cancel reply

Your email address will not be published. Required fields are marked *

14 − nine =

Related products

Class II laminar flow hood type A2 gray

Laminar Flow Hood Class II A2

Laminar flow hoods
Class II laminarflow hood catalog, type A2
Quick view
laminar flow Hood Class II - B2

laminar flow Hood Class II – B2

Chemotherapy hoods, Laminar flow hoods
laminar flow Hood Class II - B2 catalog laminar flow Hood Class II - B2 is great.
Quick view
Laminar flow hood class II type A2 green

Class II laminar flow hood, type A2

Laminar flow hoods
Class II laminarflow hood catalog, type A2
Quick view
Weighing Booth (Sampling Booth)

Weighing Booth (Sampling Booth)

Laminar flow hoods
Weighing Booth (Sampling Booth) catalog
Quick view
Biological Safety Cabinet Class III

Biological Safety Cabinet Class III

Laminar flow hoods
Class III Biosafety Cabinet is totally enclosed and gas-tight with ULPA/ HEPA filtered supply and exhaust air. Work is performed
Quick view

With years of experience, Raadlabco is ready to serve hospitals, medical centers, and pharmacies.

5th unit, 3rd floor, Arad Building, corner of Beist Alley, between Zahid and Tayeb, Mirdamad St, Isfahan
Phone: 32342754-031 – 32342798-031
Phone: 09120139181 – 09130220920
Email: info@raadlabco.com
Working hours: Saturday to Wednesday 8:15 to 16:45
Thursdays 8:15 to 12:30

Recent Posts

Useful links

  • Chemical hoods
  • Pathology hoods
  • Isolator
  • Laminar flow hoods
All rights reserved Raadlabco
  • Menu
  • Categories
  • Chemical hoods
  • Pathology hoods
  • Isolator
  • Laminar flow hoods
  • Raadlabco
  • Shop
    • Isolator
    • Laminar flow hoods
    • Pathology hoods
    • Chemical hoods
    • Chemotherapy hoods
    • Accessories
    • Laboratory equipment and scaffolding
  • Our Services
  • About us
  • Contact us
  • Login / Register
Laminar Airflow (LAF)

Laminar Airflow (LAF)

Start typing to see products you are looking for.
تماس